Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
3.
Dig Endosc ; 2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-38433317

RESUMO

OBJECTIVES: Texture and color enhancement imaging (TXI) reportedly improves the identification of the papilla of Vater for selective biliary cannulation compared with white light imaging (WLI). This multicenter study evaluated the efficacy of short-type single-balloon enteroscopy (SBE)-assisted biliary cannulation using a new-generation image-enhanced endoscopy processing system equipped with TXI in patients who underwent Roux-en-Y gastrectomy. METHODS: Patients with Roux-en-Y gastrectomy with a native papilla, and underwent short SBE-assisted biliary cannulation during endoscopic retrograde cholangiopancreatography-related procedures between January 2019 and April 2023 were retrospectively reviewed. Outcomes of biliary cannulation using TXI and WLI were compared. The primary outcome was time to successful biliary cannulation. RESULTS: Thirty-three patients underwent biliary cannulation with TXI and 98 underwent WLI. The biliary cannulation success rates and median time to successful biliary cannulation with TXI and WLI were 93.9% (95% confidence interval [CI] 79.8-99.3%) and 83.7% (95% CI 74.8-90.4%), respectively (P = 0.14), and 10 min (interquartile range [IQR] 2.5-23.5) and 18 min (IQR 9.75-24), respectively (P = 0.04). Biliary cannulation with TXI required a shorter cannulation time than that required with WLI. Adverse event rates with TXI and WLI did not differ significantly (P = 0.58). Multivariate linear regression analysis showed that the use of TXI and short length of oral protrusion were associated with a shorter successful biliary cannulation time. CONCLUSION: Short SBE-assisted biliary cannulation was effective and safe on TXI in patients who underwent Roux-en-Y gastrectomy, and achieved shorter successful biliary cannulation time.

6.
VideoGIE ; 9(3): 137-140, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38482474

RESUMO

Video 1Selective biliary cannulation was difficult, and the catheter tended to be cannulated into the pancreatic duct. We applied a double-wire technique to achieve biliary cannulation. Finally, selective biliary cannulation was achieved. Cholangiography revealed a small stone of approximately 5 mm in the common bile duct (red arrow). Subsequently, endoscopic papillary balloon dilation (EPBD) was performed using a new EPBD catheter with a diameter of 8 mm. This new EPBD catheter was inserted. We inflated this EPBD catheter slightly while observing both endoscopy and fluoroscopy monitors to confirm its dilation process. EPBD was easily and effectively performed without slipping in or out of the papilla. The orifice of the papilla was dilated. Stone extraction was completely achieved.

9.
Clin Endosc ; 57(2): 237-245, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38273220

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions. METHODS: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S). RESULTS: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03). CONCLUSION: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

14.
Gastrointest Endosc ; 99(2): 193-203.e5, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37709151

RESUMO

BACKGROUND AND AIMS: We compared ERCP using a balloon-assisted endoscope (BE-ERCP) with EUS-guided antegrade treatment (EUS-AG) for removal of common bile duct (CBD) stones in patients with Roux-en-Y (R-Y) gastrectomy. METHODS: Consecutive patients who had previous R-Y gastrectomy undergoing BE-ERCP or EUS-AG for CBD stones in 16 centers were retrospectively analyzed. RESULTS: BE-ERCP and EUS-AG were performed in 588 and 59 patients, respectively. Baseline characteristics were similar, except for CBD diameter and angle. The technical success rate was 83.7% versus 83.1% (P = .956), complete stone removal rate was 78.1% versus 67.8% (P = .102), and early adverse event rate was 10.2% versus 18.6% (P = .076) in BE-ERCP and EUS-AG, respectively. The mean number of endoscopic sessions was smaller in BE-ERCP (1.5 ± .8 vs 1.9 ± 1.0 sessions, P = .01), whereas the median total treatment time was longer (90 vs 61.5 minutes, P = .001). Among patients with biliary access, the complete stone removal rate was significantly higher in BE-ERCP (93.3% vs 81.6%, P = .009). Negative predictive factors were CBD diameter ≥15 mm (odds ratio [OR], .41) and an angle of CBD <90 degrees (OR, .39) in BE-ERCP and a stone size ≥10 mm (OR, .07) and an angle of CBD <90 degrees (OR, .07) in EUS-AG. The 1-year recurrence rate was 8.3% in both groups. CONCLUSIONS: Effectiveness and safety of BE-ERCP and EUS-AG were comparable in CBD stone removal for patients after R-Y gastrectomy, but complete stone removal after technical success was superior in BE-ERCP.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Cálculos Biliares , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos Retrospectivos , Cálculos Biliares/diagnóstico por imagem , Cálculos Biliares/cirurgia , Gastrectomia , Ducto Colédoco , Endoscópios , Resultado do Tratamento
15.
J Hepatobiliary Pancreat Sci ; 31(1): e3-e4, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37799002

RESUMO

Deviation of the bile duct orifice due to a large periampullary diverticulum presents difficulty in identifying the bile duct orifice, resulting in failure to achieve selective biliary cannulation. Tanisaka and colleagues demonstrate the usefulness of texture and color enhancement imaging for the identification of a deviated bile duct orifice.


Assuntos
Divertículo , Duodenopatias , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Divertículo/diagnóstico por imagem , Divertículo/cirurgia , Cateterismo/métodos , Diagnóstico por Imagem , Ductos Biliares
17.
Dig Endosc ; 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37921041

RESUMO

OBJECTIVES: We aimed to clarify the clinical utility of measuring serum pancreatic enzymes after endoscopic retrograde cholangiopancreatography (ERCP) for the purpose of predicting post-ERCP pancreatitis (PEP) by a meta-analysis of diagnostic test accuracy studies. METHODS: Studies on the prediction accuracy of PEP by serum amylase or lipase measured at 2, 3, and 4 h after ERCP were collected. A literature search was performed in PubMed and the Cochrane Library database for studies published between January 1980 and March 2023. The quality of individual studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2. Data were analyzed using Meta-DiSc 2.0 software. RESULTS: We searched the databases and identified 20 observational studies (12,313 participants). PEPs were defined according to criteria by Cotton or modified Cotton, revised Atlanta criteria, or the Japanese criteria. Meta-analysis of eight studies (4389 participants) showed a pooled sensitivity of 71.1% (95% confidence interval [CI] 56.1-82.5) and pooled specificity of 91.2% (95% CI 85.9-94.6) for the serum amylase cut-off value at 3 times the upper limit of normal (ULN). Another meta-analysis of five studies (1970 participants) showed a pooled sensitivity of 85.8% (95% CI 61.9-95.7) and pooled specificity of 85.3% (95% CI 81.9-88.1) for the serum lipase cut-off value at 3 times ULN. CONCLUSION: Despite a high risk of bias due to various reference standards, this updated meta-analysis and the utility assessment by a decision tree showed the utility of serum amylase or lipase levels more than 3 times ULN measured 2-4 h after ERCP for predicting PEP.

18.
BMC Gastroenterol ; 23(1): 339, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37784019

RESUMO

BACKGROUND: Fluoropyrimidine-based postoperative adjuvant chemotherapy is globally recommended for high-risk stage II and stage III colon cancer. However, adjuvant chemotherapy is often associated with severe adverse events and is not highly effective in preventing recurrence. Therefore, discovery of novel molecular biomarkers of postoperative adjuvant chemotherapy to identify patients at increased risk of recurrent colorectal cancer is warranted. Autophagy (including mitophagy) is activated under chemotherapy-induced stress and contributes to chemotherapy resistance. Expression of autophagy-related genes and their single-nucleotide polymorphisms are reported to be effective predictors of chemotherapy response in some cancers. Our goal was to evaluate the relationship between single-nucleotide variants of autophagy-related genes and recurrence rates in order to identify novel biomarkers that predict the effect of adjuvant chemotherapy in colorectal cancer. METHODS: We analyzed surgical or biopsy specimens from 84 patients who underwent radical surgery followed by fluoropyrimidine-based adjuvant chemotherapy at Saitama Medical University International Medical Center between January and December 2016. Using targeted enrichment sequencing, we identified single-nucleotide variants and insertions/deletions in 50 genes, including autophagy-related genes, and examined their association with colorectal cancer recurrence rates. RESULTS: We detected 560 single-nucleotide variants and insertions/deletions in the target region. The results of Fisher's exact test indicated that the recurrence rate of colorectal cancer after adjuvant chemotherapy was significantly lower in patients with the single-nucleotide variants (c.1018G > A [p < 0.005] or c.1562A > C [p < 0.01]) of the mitophagy-related gene PTEN-induced kinase 1. CONCLUSIONS: The two single-nucleotide variants of PINK1 gene may be biomarkers of non-recurrence in colorectal cancer patients who received postoperative adjuvant chemotherapy.


Assuntos
Neoplasias Colorretais , Recidiva Local de Neoplasia , Humanos , Estudos Retrospectivos , Recidiva Local de Neoplasia/genética , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/genética , Neoplasias Colorretais/patologia , Biomarcadores , Quimioterapia Adjuvante , Nucleotídeos/uso terapêutico , Estadiamento de Neoplasias , Fluoruracila/uso terapêutico , Biomarcadores Tumorais/genética , PTEN Fosfo-Hidrolase/genética
19.
Intern Med ; 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37779059

RESUMO

The incidence of neuroendocrine carcinomas arising from the bile duct is low, and that of mixed neuroendocrine-non-neuroendocrine neoplasms (MiNENs) is even lower; therefore, there is no standard treatment for MiNENs. Choosing the appropriate treatment in clinical practice is difficult. We herein report a case of unresectable extrahepatic bile duct MiNEN in a 66-year-old man who received curative chemoradiotherapy and achieved a complete response, remaining recurrence-free for 2.5 years. We consider the findings of this case to be valuable in selecting a treatment strategy for unresectable bile duct MiNENs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...